  • Micro processor controlled, brush free synchronized motor = consistent bolt tightening quality - suitable for all international networks from 100-253 Volt and 45-66 Hz as well as for operation on generators
  • Highest precision - consistent bolt tigthening quality
  • Bolt tension program via torque and with automatic de-tension (10° left )(d)
  • Bolt tension program with pre-torque and torsion angle (option plus)
  • Menu selection and torque/angle display via integrated LC-panel
  • Moisture and Splash resistant version (IP) available - ideal for site work
  • Solid, enclosed cast aluminium housing
  • NEW: Type ECWip with integrated angle head - ideal for confined areas


NEW: Alkitronic EFC Electric Compact Torque Wrench

Cost-effective model with LED display - not weatherproof
Photo Type /
Model-No.
Torque
ca.Nm *
Square Drive Ø mm
Lenght
mm
Idle speed
1/min
Weight**
kg
D1 D2 D3
Alkitronic EFCDimension
EFC 40
60 - 450 3/4" 41 85 88 330 19 8.8
EFC 80 150 - 840 3/4" 41 85 88 330 12 8.8
EFC 120 200 - 1250 3/4" 41 85 88 330 8 10
1" 54
EFC 200 400 - 2100 1" 54 85 88 375 7 10
EFC 280 500 - 2800 1" 54 85 88 382 6 10.6
EFC 350 660 - 3600 1 1/2" 72 98 98 400 4 12.5
EFC 500 900 - 5'000 1 1/2" 72 105 110 438 2 17.8
Motors for all models: 110-253 Volt, Frequency 45-66 Hz, max. power 2000 Watt

* In order to be able to loosen bolts please add 20 % on top of the max. required tightening torque. Continous operation at maximum load will activate the thermal overlad protection and shut off the tool.

** Weight without torque reaction arm


back to top

Allweather Electric Torque Wrench Type EFCip and EFCip plus - Electric Shut-off torque wrenches
Moisture- and splash water resistant, CE certified, protection class IP 54
Photo Type /
Model-No.
Torque
ca.Nm *
Square Drive Ø mm
Lenght
mm
Idle speed
1/min
Weight**
kg
D1 D2 D3

EFCip - EFCip plus 10
70 - 400 3/4" 41 85 88 330 76 9.0
EFCip - EFCip plus 20 80 - 600 3/4" 41 85 88 330 38 9.0
EFCip - EFCip plus 30 150-1000 3/4" 41 85 88 330 24 9.0
EFCip - EFCip plus 40 250-1500 1" 54 85 88 382 15 10.0
EFCip - EFCip plus 50 300-1800 1" 54 85 88 382 13 10.0
EFCip - EFCip plus 60 450-2500 1" 72 98 98 400 12 11.0
EFCip - EFCip plus 70 600-3500 1 1/2" 72 98 98 400 9 13.2
EFCip - EFCip plus 80 800-4200 1 1/2" 72 98 98 406 7 13.2
EFCip - EFCip plus 90 1000-5000 1 1/2" 72 98 98 428 6 17.5
EFCip - EFCip plus 100 1300-6300 1 1/2" 72 98 98 436 4 18.5
Motors for all models: 110-253 Volt, Frequency 45-66 Hz, max. power 2000 Watt

* In order to be able to loosen bolts please add 20 % on top of the max. required tightening torque. Continous operation at maximum load will activate the thermal overlad protection and shut off the tool.

** Weight without torque reaction arm

back to top

NEW: Alkitronic Electric Right Angle Torque Wrench Type ECW
Cost-effective model with LED display - not weatherproof

Photo Type /
Model-No.
Torque
ca.Nm *
Square Drive Ø mm
Lenght
mm
Height
mm
Idle speed
1/min
Weight**
kg
D1 D2 D3

ECW Alkitronic Winkel Drehmomentschrauber

 

 

ECW 40
60 - 450 3/4" 41 85 88 302 249 20 11.8
ECW 80 150 - 840 3/4" 41 85 88 302 249 13 11.8
ECW 120 200 - 1250 3/4" 41 85 88 302 280 9 12.4
1" 54 330 13.0
ECW 200 400 - 2100 1" 54 85 88 302 300 8 13.0
ECW 280 500 - 2800 1" 54 85 88 302 300 7 13.6
ECW 350 660 - 3600 1 1/2" 72 98 98 316 315 4 15.5
ECW 500 900 - 5'000 1 1/2" 72 105 110 320 350 2 16.8
Motors for all models: 110-253 Volt, Frequency 45-66 Hz, max. power 2000 Watt

* In order to be able to loosen bolts please add 20 % on top of the max. required tightening torque. Continous operation at maximum load will activate the thermal overlad protection and shut off the tool.

** Weight without torque reaction arm

ECW Dimensions
back to top
Allweather Angle Head Electric Torque Wrench Type ECWip and ECWip plus - Electric Shut-off torque wrenches
Moisture- and splash water resistant, CE certified, protection class IP 54
Photo Type /
Model-No.
Torque
ca.Nm *
Square Drive Ø mm
Lenght
mm
Idle speed
1/min
Weight**
kg
D1 D2 D3

Allweather Angle Head Electric Torque Wrench Type EWCip and EWCip plus

 

 

ECWip - ECWip plus 10
60 - 420 3/4" 41 85 88 310 78 12.0
ECWip - ECWip plus 20 80 - 620 3/4" 41 85 88 310 40 12.0
ECWip - ECWip plus 30 150-1050 3/4" 41 85 88 310 26 12.0
ECWip - ECWip plus 40 250-1510 1" 54 85 88 310 17 13.0
ECWip - ECWip plus 50 300-1830 1" 54 85 88 310 15 14.0
ECWip - ECWip plus 60 450-2430 1" 72 98 98 310 14 14.0
ECWip - ECWip plus 65 450-3000 1" 72 98 98 310 14 14.0
ECWip - ECWip plus 70 600-3480 1 1/2" 72 98 98 318 11 16.0
ECWip - ECWip plus 80 750-4260 1 1/2" 72 98 98 318 9 16.0
ECWip - ECWip p plus 90 980-5030 1 1/2" 72 98 98 326 6 16.0
ECWip - ECWip plus 100 1260-6480 1 1/2" 72 98 98 315 3.5 18.0
Motors for all models: 110-253 Volt, Frequency 45-66 Hz, max. power 2000 Watt

* In order to be able to loosen bolts please add 20 % on top of the max. required tightening torque. Continous operation at maximum load will activate the thermal overlad protection and shut off the tool.

** Weight without torque reaction arm

ECWip Dimensions
back to top

Detailed description

Blocking pin for use of the machine as rigid version (fixed joint motor/gearbox)
Blocking pin for use of the machine as rigid version (fixed joint motor/gearbox)

One-handed operation, four-edge operation button for clock wise, counter clock wise, toggle start and start commands
One-handed operation, four-edge operation button for clock wise, counter clock wise, toggle start and start commands

  • Primary operation unit: on/off switch of the machine; One-handed operation: comfortable, slow right/left rotation for safe and precise positioning of the torque wrench (toggle switch) as well as for the starting of the bolt tightening process.
  • Speed, frequency and torque are correspondingly regulated and controlled. Microcontrolled monitoring combined with a processor controlled switch-off electronic guarantee a precise repeatability of the pre-set torque.Repeatable accuracy for shut-off is +/- 5% for identically soft and hard joints.
  • Integrated motor protection: for safety reasons an automatic thermal overload switch is built in as well as a permanent cooling fan that keeps running after the safety shut-off and thus provides short periods of cooling.
  • Two principles of construction within one tool:
    A = swivelling: free joint tool - the drive unit (motor) can independent of the gear box be fully rotated even when the reaction arm is already in its position
    B = Rigid: Fixed joint between motor and gear box - mechanically reversible
Secondary operation unit - Type EFC
  • Secondary operation unit - Type EFC

    LED-Display
    : light-emitting diode displays the pre-set torque within 19 stages together with the direction of rotation
programm selection - esc
programm selection - esc
  • Secondary operation unit - Type EFCplus
    (provision of functions dependent of the torque type):
    Display and adjustment of shut-off torques, sense of rotation, angle, loosening, rotations in angle degrees or number of rotations incl. menu operation etc.
back to top
spacer
© 2002 - 2012 Peter Hold Ltd - all rights reserved
Disclaimer
- Links - Site map - Contact

website design & development by emazing international :: last updated 27.1.12